How the equipment works

How long a well pump lasts, and what actually shortens it

People ask how many years a well pump lasts. The more useful question is how many starts it has left, because a pump's life is spent far more by starting than by running, and almost every early failure we see traces back to something making it start too often.

Call (904) 675-0005Request a quote

The short answer

  • Service life is set by how many times a pump starts, not by how many years it has been in the ground.
  • The three things that shorten it most: short cycling, a pump oversized for the well, and lightning.
  • Maintenance is minimal: check the tank's air charge against the switch setting and deal with short cycling immediately.

Starts, not years

Two identical pumps installed on the same day can be a decade apart in service life. The one on a healthy pressure tank starts a handful of times an hour. The one on a waterlogged tank starts every few seconds all day.

This is why we treat a short-cycling complaint as urgent even though nothing appears to be broken. The damage is accumulating in the part that is expensive to reach.

Sizing

A pump matched to a well's depth and recovery rate runs within itself. A pump that can move more water than the formation can deliver draws the level down, pulls air and sand, and overheats.

Replacing like for like is only correct if the pump that came out was right in the first place. Sometimes it was not, and the fact that it failed early is the evidence.

Water quality

Sand is abrasive and wears impellers. High iron builds deposits. Hydrogen sulfide and low pH are hard on metal components. None of these are unusual in Northeast Florida, which is part of why water testing is not a separate concern from equipment life.

Lightning

Florida gets more lightning than almost anywhere in the country, and a well pump is a motor at the end of a long wire running into the ground. Surge damage to control boxes and motors is a genuine and regular cause of failure here in a way it is not in most of the country.

What good maintenance actually consists of

Very little, and that is the point. Check the pressure tank's air charge against the switch setting, keep an eye on the gauge so you notice a change in the cycle, deal with short cycling immediately, and test the water periodically. A well system is not a boiler; it does not need an annual service contract to survive.

Common questions

Is there a typical service life?
There is a wide range, and any single number quoted without knowing the well, the water and the cycle count is a guess. We would rather look at the system and tell you what condition yours is in.
Should I replace a working pump preventively?
Generally no. The exception is when a pump has to come out of the ground anyway for another reason, at which point replacing an old pump while it is already at the surface can be the sensible economics.

Rather have somebody look at it

Call and describe what the system is doing.

Call (904) 675-0005 Request a quote