A well pump is supposed to run in bursts. One that never shuts off is either trying to fill something that keeps emptying, or being told by a faulty switch that the pressure never got high enough. Either way it is running itself to death, so this is not a problem to leave over a weekend.

Call (904) 675-0005Request a quote

The short answer

  • A pump that never shuts off is either chasing a leak or being misread by a failed pressure switch.
  • Isolate the house at the main valve: if pressure holds, the leak is indoors.
  • Switch the breaker off until it is fixed. A pump running dry overheats the expensive half of the assembly.

It cannot reach cut-off pressure

A pressure switch turns the pump off at a set pressure, commonly around 50 or 60 pounds per square inch. If the system never gets there, the switch never opens and the pump never rests.

The reasons it cannot get there are a worn pump that has lost lift, a leak in the drop pipe inside the well, a failed check valve letting water fall back down the casing, or a water level in the well that has dropped so far that the pump is drawing air part of the time.

Something downstream is leaking

A pump chasing a leak looks identical to a failing pump from the gauge. The difference is where the water is going.

The usual suspects are a running toilet, an irrigation zone with a cracked line, a stuck float on a livestock trough, or a leaking pipe under a slab. A leak big enough to keep a pump running is usually big enough to find: close the main valve into the house and watch the gauge. If pressure holds with the house isolated, the leak is in the house. If it still falls, the leak is between the well and that valve.

The pressure switch itself has failed

Switch contacts weld shut, and the small tube that feeds pressure to the switch clogs with iron or sediment. Either way the switch stops seeing what the system is really doing. In Northeast Florida the clogged tube is common, because iron is common.

Why it matters more than it sounds

A submersible pump is cooled by the water flowing past it. A pump running dry or running continuously against a leak overheats, and the motor is the expensive half of the assembly. Turning the breaker off until somebody looks at it is usually the cheapest decision available.

Common questions

Should I turn the pump off if it will not stop running?
Usually yes. If there is no water being used and the pump is still running, switching off the breaker protects the motor. You lose water until it is fixed, which is a smaller loss than the pump.
Could it just be that we are using a lot of water?
It can be. Filling a pool, running several irrigation zones, or a long laundry day can keep a correctly sized pump running for a long stretch. The test is whether it shuts off within a few minutes once everything is turned off.