WELL & PUMP

Northeast Florida and Panama City nine counties served

Home / Services / Well Pump Repair

Well Pump Repair

Well pump repair across Northeast Florida

Most calls that start with no water do not end with a new pump. They end with a pressure switch, a pressure tank, a control box or a corroded connection. The job is to find out which, before anything expensive comes out of the ground.

Call (904) 675-0005Request a quote

Section through a Northeast Florida water wellA cut through the ground: a capped wellhead above grade, casing descending through sand and a clay confining layer into the limestone of the Floridan aquifer, the static water level, and a submersible pump near the bottom of the well. Depths are proportional, not to scale.Pressure tankStatic waterlevelPumpGROUND LEVELSand, water tableClay, confining layerLIMESTONE, FLORIDANProportional, not to scale.Section through a Northeast Florida water wellAn engineering section through the ground: a structure at the surface, a capped wellhead standing clear of grade, steel casing descending through a sand surficial zone and a clay confining layer into the limestone of the Floridan aquifer, the static water level, a submersible pump on a drop pipe near the bottom of the well, and the pressure tank it delivers to. Strata are hatched to convention and depths are proportional rather than to scale.04080120160Pressure tankStatic water levelunder artesian pressureSubmersible pumpGROUND LEVELSand, surficial water tableClay, confining layerLIMESTONE, FLORIDAN AQUIFERProportional, not to scale. Real depths vary across the region.
Water off right now?(904) 675-0005

Call us when

A diagnosis first, so you are not paying to replace a working pump

  • No water at any tap
  • Pressure that drops away when a tap opens
  • The pump running and never shutting off
  • Rapid clicking on and off at the tank
  • Air spitting from the taps
  • Sandy or cloudy water
  • A breaker that trips when the pump starts

The pump is the last thing we suspect, not the first

On a submersible system the pump is at the bottom of a few hundred feet of pipe and wire. Everything else, the switch, the tank, the control box, the wiring and the valves, is above ground where it can be tested in minutes.

So that is the order we work in. Testing the cheap accessible parts first is not caution, it is arithmetic: pulling a pump to find the fault was a twelve dollar switch is a bad afternoon for everybody.

What the symptom tells us

A pump that runs and never stops is chasing a leak or being misread by a switch. A pump that clicks on and off every few seconds is almost always a pressure tank that has lost its air charge. A pump that hums without delivering is a jet pump that has lost prime. Silence with power at the switch is the switch or the pump itself.

Air spitting at the taps, or water that has turned sandy, points at the well rather than the equipment: a level that has dropped, or a pump drawing harder than the formation can supply.

What we can repair and what we cannot

Pressure switches, gauges, pressure tanks, control boxes, capacitors, relays, wiring, check valves, pitless adapters and above-ground plumbing are all repairs.

A submersible motor that has failed electrically is a replacement, not a repair. When that is the answer we say so plainly and show you the reading that proves it, because a diagnosis you cannot check is just an assertion.

How it works

Tell us what the pump is doing

Running constantly, clicking rapidly, humming, or silent. Those four answers point at four different failures and decide what goes on the truck.

We test from the switch back toward the well

Power, pressure switch, tank charge, control box, then the pump circuit. Each step either clears a component or finds the fault.

You get told which part failed and why

Along with what it costs to put right, before the work starts rather than after it.

Common questions

Do you charge to diagnose?
There is a call-out for coming to look, and we will tell you what it is when you call. What we will not do is quote a repair over the phone for a fault nobody has seen yet.
Can you tell me what is wrong over the phone?
Often we can narrow it to two or three likely causes, which is genuinely useful because it decides what we bring. We will not tell you it is definitely the pump without testing, because it usually is not.

Well Pump Repair across nine counties across Northeast Florida, plus Panama City

Call and describe what is happening. It decides what we bring.

Call (904) 675-0005 Request a quote

Call (904) 675-0005 Request a quote