WELL & PUMP

Northeast Florida and Panama City nine counties served

Home / Well Pump Repair / Callahan

narrowing the fault over the phone before the truck is loaded

Well Pump Repair in Callahan

Most no-water calls in Callahan can be narrowed to one of three things before anyone drives out.

Call (904) 675-0005Request a quote

Section through a Northeast Florida water wellA cut through the ground: a capped wellhead above grade, casing descending through sand and a clay confining layer into the limestone of the Floridan aquifer, the static water level, and a submersible pump near the bottom of the well. Depths are proportional, not to scale.Pressure tankStatic waterlevelPumpGROUND LEVELSand, water tableClay, confining layerLIMESTONE, FLORIDANProportional, not to scale.Section through a Northeast Florida water wellAn engineering section through the ground: a structure at the surface, a capped wellhead standing clear of grade, steel casing descending through a sand surficial zone and a clay confining layer into the limestone of the Floridan aquifer, the static water level, a submersible pump on a drop pipe near the bottom of the well, and the pressure tank it delivers to. Strata are hatched to convention and depths are proportional rather than to scale.04080120160Pressure tankStatic water levelunder artesian pressureSubmersible pumpGROUND LEVELSand, surficial water tableClay, confining layerLIMESTONE, FLORIDAN AQUIFERProportional, not to scale. Real depths vary across the region.
Water off right now?(904) 675-0005

A pump that has stopped is not one fault, it is a family of them, and they need different parts. The motor may have failed. The pressure switch may have burned its contacts. The control box capacitor may have gone. The drop pipe may have parted and left a working pump pushing water back down its own borehole. From the tap, all four look identical: nothing comes out.

That matters more in Callahan than it does somewhere with a meter, because there is no fallback supply while the diagnosis happens. So the phone call does real work. Three questions settle most of it. Is the breaker for the well tripped, and does it trip again immediately when reset. Does the pressure gauge on the tank read anything at all, or is it sitting flat on zero. And can you hear anything at the wellhead, a hum, a click, or silence.

Those answers decide what goes on the truck. A tripped breaker that trips again points at the motor or the wiring down the well and means bringing the equipment to pull it. A gauge holding pressure with no water at the tap is usually not the pump at all, it is a valve or the tank. Silence at the head with a healthy breaker often means the control box, which is the cheapest of these and the one most often replaced unnecessarily. Telling us what you can see is what stops the second trip.

Permits. Callahan is in Nassau County, where a well permit is issued by the Florida Department of Health in Nassau County. What that involves.

Asked in Callahan

Questions

What should I check before calling?

The breaker and the pressure gauge, in that order. Do not reset a breaker more than once if it trips again straight away, because that usually means a fault down the well and repeated resets can damage the motor further. Note what the gauge reads and whether it moves.

Can a pump be repaired, or does it always get replaced?

Plenty of no-water calls are repairs rather than replacements. Pressure switches, control boxes, capacitors and pressure tanks are all serviceable items above ground. What is not economic to repair is a submersible motor that has failed down the well, because the cost of the visit is in pulling it either way.

Well Pump Repair in Callahan

Call and describe what the water is doing.

Call (904) 675-0005 Request a quote

Call (904) 675-0005 Request a quote