WELL & PUMP

Northeast Florida and Panama City nine counties served

Home / Well Pump Repair / Sanderson

power supply as the first suspect, not the last

Well Pump Repair in Sanderson

In Sanderson the pump is often innocent and the electricity supply is not.

Call (904) 675-0005Request a quote

Section through a Northeast Florida water wellA cut through the ground: a capped wellhead above grade, casing descending through sand and a clay confining layer into the limestone of the Floridan aquifer, the static water level, and a submersible pump near the bottom of the well. Depths are proportional, not to scale.Pressure tankStatic waterlevelPumpGROUND LEVELSand, water tableClay, confining layerLIMESTONE, FLORIDANProportional, not to scale.Section through a Northeast Florida water wellAn engineering section through the ground: a structure at the surface, a capped wellhead standing clear of grade, steel casing descending through a sand surficial zone and a clay confining layer into the limestone of the Floridan aquifer, the static water level, a submersible pump on a drop pipe near the bottom of the well, and the pressure tank it delivers to. Strata are hatched to convention and depths are proportional rather than to scale.04080120160Pressure tankStatic water levelunder artesian pressureSubmersible pumpGROUND LEVELSand, surficial water tableClay, confining layerLIMESTONE, FLORIDAN AQUIFERProportional, not to scale. Real depths vary across the region.
Water off right now?(904) 675-0005

A submersible pump is an electric motor at the bottom of a hole, and everything it does depends on getting clean, adequate power down a long cable. Out here that supply is less consistent than it is on a suburban street. Rural feeders are longer, storms take them down more often, and the run from the meter to a wellhead sitting well away from the house adds voltage drop of its own.

The failures that produces are mostly not pump failures. A motor starting on low voltage draws more current, runs hotter and can trip its overload, which reads as a pump that keeps cutting out. A control box capacitor degraded by repeated surges will leave a motor humming without starting. A pressure switch with contacts pitted by years of arcing under an unstable supply will chatter or fail to close at all. In each case the pump in the ground is fine and the fault is between the panel and the wellhead.

Which is why the diagnostic order here runs from the breaker outward rather than from the well inward. Breaker, disconnect, control box, switch, wiring, and only then the pump. It is also why a household that has just had a storm and lost water should say so on the phone, because it changes what we expect to find and, often enough, means the repair is a component at the surface rather than anything that has to be pulled.

Permits. Sanderson is in Baker County, where a well permit is issued by the Florida Department of Health in Baker County. What that involves.

Asked in Sanderson

Questions

We lost power in a storm and now there is no water. Is the pump destroyed?

Often not. Surges and outages most commonly take out the control box capacitor, the pressure switch or a breaker, all of which are at the surface and straightforward to replace. It is worth checking those before assuming the worst.

The pump hums but does not start. What does that mean?

A hum without a start usually points at the starting circuit rather than the motor itself, most often a failed capacitor in the control box. It is one of the more common faults out here and one of the less expensive ones.

Well Pump Repair in Sanderson

Call and describe what the water is doing.

Call (904) 675-0005 Request a quote

Call (904) 675-0005 Request a quote